405 Touch Microplate Washer
The new 405™ Touch Microplate Washer incorporates a state-of-the-art, high resolution LED backlit touch screen user interface for intuitive and flexible onboard instrument control of 96- and 384-well microplate washing. A 5.7 inch graphical color display seamlessly guides users through protocol development, instrument maintenance and daily use at the touch of a finger. Two USB flash drive ports enable convenient file transfer, storage and operation. For those who prefer computer control or require 21 CFR Part 11 compliance, the 405 Touch can be controlled with optional Liquid Handling Control™ Software.
For over 27 years, BioTek has continued to advance the art of automated microplate washing, resulting in the industry leading ELx405™, which set the standard in full 96- and 384-well washing. The 405 Touch, maintains all the features of the ELx405™ Microplate Washer while adding a new, modern and powerful interface to again reshape the day-to-day routines of today’s life science laboratories. Fast and efficient vacuum filtration, high strength biomagnetic separation, patented Dual-Action™ manifolds, optimized cell washing for loosely adherent cell monolayers and patent-pending Ultrasonic Advantage™ are all available. New key features include automated internal 4-buffer switching and quick release manifolds for easy maintenance and modular use.
Scientists regard unexpected clogging of manifold tubes to be the largest contributor to assay failure. BioTek’s washers with their built-in ultrasonic cleaners are the only instruments of their kind available today able to automatically prime with cleaning solution, sonicate manifold tubes to remove protein or salt crystal build up and re-prime with buffer leaving the instrument clean and ready for its next wash. Cleaning these tubes is a time consuming and labor intensive process. BioTek's Ultrasonic Advantage™ incorporates the power of ultrasonic cleaning to make the 405 Touch a self-maintaining microplate washer.
For washing microsphere based assays, all 405 Touch models can be equipped with accessory modules for both vacuum filtration and biomagnetic separation. This allows for full plate washing of polystyrene and magnetic beads used in a growing number of multiplex assays and bead-based ELISAs, such as those developed on the Luminex® xMAP® technology platform. The 405 Touch’s vacuum filtration feature automates the wash steps of filter bottom plates with five different vacuum levels for optimal performance of filter pore sizes ranging from 0.45 µm to 1.2 µm. Developed with leaders in genotyping, gene expression and protein assays, the 405 Touch’s biomagnetic separation incorporates a range of immobilization options each with high-energy neodymium iron boron magnets for rapid separation of micrometer and nanometer beads with superior retention. The 405 Touch is Luminex® xMAP® approved.
The 405 Touch Washer, also known as the 405 TS Series, is available in a range of configurations for different microplate formats and wash requirements. The 405 HT TS is designed specifically to rapidly wash 384-well microplates and includes BioTek's patented Dual-Action™ 192-tube manifold to ensure optimal performance. A proprietary tube-in-tube aspiration manifold design also provides complete 384-well evacuation even with buffers not containing surfactant. The 405 Select TS offers the patented Dual-Action™ manifold in a 96-tube format, providing independent control of both dispense and aspirate manifolds for precise overfill washing and overflow protection. This unique design washes both 96- and 384-well plates without the need for any hardware changes. With its angled dispense tubes, full control of dispense and aspiration rates and unique X, Y, Z positioning, the 405 Select TS is ideal for the most demanding wash requirements including loosely-adherent cell lines. For those applications that use only 96-well microplates, the standard 405 TS is an ideal choice with unique features to lower background absorbance values and increase the signal-to-noise ratio of typical ELISA assays.
With its color graphical user interface and wide application range, the new 405 Touch Microplate Washer is an easy to use, total solution for 96- and 384-well plate washing in a compact and robot-compatible design.
Applications:
- ELISAs
- MSD assays
- HCS immune cytochemistry
- FLIPR Ca2+ flux
- Cell-based assays
- Magnetic and polystyrene bead processing (gene expression assays, cytokine assays)
- ELISPOT assays
US Federal Government customers: This product is available on GSA contract. Contact BioTek Customer Care with questions or submit a Quote Request Form to receive pricing and information on specific models (please note 'GSA Contract' in the Comments field).
xMAP® is a registered trademark of Luminex® Corporation.
Hardware:
- Accommodates 96- and 384-well microplates
- High resolution, LED backlit touch screen UI for intuitive and flexible onboard washer control
- 5.7 inch graphical color display seamlessly guides users through protocol creation, instrument maintenance and daily use at the touch of a finger
- Fast Intel Atom processor running Windows CE
- Resistive touch screen display
- Supports all gloved environments
- Compatible with widest range in humidity levels
- May be operated with pointing devices
- Low power, green technology - Two USB flash drive ports enable convenient file transfer, storage and operation
- Especially helpful when instrument is shared between researchers
- Insert memory stick, wash plates…and go
- Each unit ships with memory stick containing sample protocols and instructional videos
- 405 HT TS
- Offers fast 384-well washing with patented 192-tube Dual-Action™ manifold for independent dispense and aspiration control for precise overfill washing and overflow protection
- 405 Select TS
- Accommodates 96-/384-well washing with patented 96-tube Dual-Action™ manifold
- Includes optimized cell washing with two low-flow rates and 20° angled dispense tubes ideal for washing loosely adherent cell monolayers - 405 TS models automate basic 96-well dispensing and aspiration
- Includes patent-pending Ultrasonic Advantage™ – built in ultrasonic cleaner for manifold self-maintenance
- Equipped with superior tube-in-tube aspiration manifold design for 384-well washing with buffers not containing surfactant
- Also calibrated for accessory 96-tube Dual-Action manifold for 96-well washing
- Automated internal 4-buffer switching
- Internal positive displacement pump eliminates use of troublesome pressure delivery systems and allows use of any size dispense reservoir
- Inline filtration within each dispense bottle
- Built-in priming trough allows automatic manifold priming and rinsing during both operation and maintenance modes and eliminates need for blank plates when used in automated robotic systems
- All washers vacuum filtration ready (accessory filtration modules sold separately)
- All washers biomagnetic separation ready (accessory magnets sold separately)
- Quick change manifold designs
- Built-in fluid flow, fluid detection, and vacuum sensing provide complete protection for unattended operation
- BioStack™ Microplate Stacker compatibility for batch processing of up to 50 ANSI/SBS standard height plates
Software:
- Context sensitive help system complete with recommendations, diagrams and images is only key press away when questions arise
- Instructional videos walk users through instrument setup and basic use
- Quick menu allows fluid paths to be easily primed, wash process started and manifold cleaned
- Predefined protocols included for out-of-box washing
- ELISA
- Cell washing
- Vacuum filtration and biomagnetic separation – Luminex® xMAP® technology workflows - Fully customizable protocol parameters for individualized wash requirements - gentle cell-washing to vigorous wash for high-binding assays
- Dispense height
- Flow rate
- Aspiration height
- Soak time
- Shake time and frequency
- Aspiration rate
- Horizontal dispense and aspirate positions
- Crosswise aspiration - AutoPrime
- Additional software flexibility and 21 CFR Part 11 compliance with Liquid Handling Control™(LHC) Software for method development, downloading and washing plates.
- Run protocols created onboard, downloaded from LHC™ Software or transferred on USB drive
Model |
Part # |
96-/384-well |
384-well |
96-well |
Optimized Cell Washing |
4-Buffer Switching |
Ultrasonic Advantage |
Biomagnetic Separation* |
Vacuum Filtration* |
| 405™ HT TS | 405TSHT |
• |
• |
• |
• |
||||
405TSHTV |
• |
• |
• |
• |
• |
||||
| 405™ Select TS | 405TSU |
• |
• |
• | • | ||||
405TSUV |
• |
• |
• |
• |
• |
||||
405TSUS |
• |
• |
• |
• |
• |
||||
405TSUVS |
• |
• |
• |
• |
• |
• |
|||
| 405™ TS | 405TSR |
• |
• | • | |||||
405TSRV |
•
|
• |
• | • | |||||
405TSRS |
• |
• | • | • | |||||
405TSRVS |
• |
• |
• | • | • |
* With available accessory module sold separately
| 405™ Touch Microplate Washer Configurations |
||
| Feature | Design | |
| HT | Faster 384-well microplate washing |
|
| V | Automated Internal 4-Buffer Switching | |
| S | Ultrasonic Advantage™ |
|
| U | 96-/384-well microplate washing |
|
| R | 96-well microplate washing |
|
| Allgemein | |
| Assays | Magnetic bead, polystyrene bead
Filtration-to-waste processes |
| Separation | Biomagnetic separation, vacuum filtration |
| Mikroplattenmodelle | 96- and 384-well (model dependent) Low profile and standard height Solid and filter bottom
|
| Schütteln | Programmable in minutes and seconds, up to 60 minutes Intensities - slow, medium, fast or variable |
| Verweilzeit | Programmable in minutes and seconds, up to 60 minutes |
| Magnet | High strength 96- and 384-well designs Choice of two designs, custom for BioTek microplate washers: Flat: - Flat-bottom well - beads pulled to band across well bottom - Round-bottom well - beads pulled to button at well bottom Ring: - beads pulled to 4-zone ring at well bottom |
| Sicherheit/Bedienung/Wartung | Waste and vacuum sensing, fluid and flow detection Aerosol cover Adjustment utility for plate positioning Overflow protection Preprogrammed maintenance routines |
| Automation | BioStack™ Microplate Stacker - up to 50 ANSI/SBS standard height plates (optional)
|
| Onboard Software | High resolution backlit LED touch screen UI 5.7 inch graphical color display Intel Atom processor running Windows CE Predefined sample wash protocols - ELISA, cell wash, magnetic beads and biomagnetic separation and vacuum filtration Quick Menu Create or edit multiple custom protocols Run protocols created onboard, downloaded from LHC™ Software or transferred on USB flash drive |
| PC-Software | Liquid Handling Control™ (LHC™), for PC wash protocol programming and execution (optional) |
| Betriebstemperatur | 15° C to 30° C (59° F to 86° F) |
| Schnittstelle | For PC control and BioStack™ integration – 1 USB port, 1 9-pin RS232 port For file transfer – 2 USB Flash Memory ports |
| Luftfeuchtigkeit | 10% to 85%, non-condensing |
| Netzspannung | 100 – 240 Volts AC 50/60 Hz, < 8.0 A |
| Waschen | |
| Waschkammtypen | 96-well washing: 96-tube (8 X 12) manifold 96-/384-well washing: Dual-Action™ 96-tube (8 X 12) manifold 384-well washing: Dual-Action™ 192-tube (16 x 12) manifold |
| Waschgeschwindigkeit | Solid bottom plates: 96-Well: 3 asp. / disp. cycles, 300 µL/well, 96-tube manifold, final aspirate: <30 seconds 384-Well: 3 asp. / disp. cycles, 100 µL/well, 96-tube manifold, final aspirate: <80 seconds 1 asp. / disp. cycle, 400 µL/well, 384 wells, 192-tube manifold, final aspirate: <20 seconds Filter bottom plates: Variable, based on wash parameters |
| Flüssigkeitzufuhr | One internal positive displacement pump |
| Vakuum Filtration | Selectable vacuum levels (approximate finals at 30 seconds): Lowest: -38 mmHg Low: -113 mmHg Medium: -200 mmHg High: -390 mmHg Highest: -506 mmHg Vacuum filtration time range: 5 to 999 seconds |
| Volumenbereich | 25 to 3,000 µL/well Selectable in 1 µL increments |
| Pufferauswahl | Internal automatic switching for up to 4 wash buffers (optional) |
| Flussraten | 1 to 11 Includes low flow, cell wash rates (model dependent) |
| Waschzyklen | 1 to 250 |
| Dosierpräzision |
|
| Restvolumen | Solid bottom plates:
optimized prior to testing
Filter bottom plates:
0.45 µm plate, filtration 30 seconds, low vacuum, blotted
µm plate, filtration 10 seconds, low vacuum, blotted |
| Sterilisation | Chemical 0.5% sodium hypochlorite, 70% isopropyl alcohol or 70% ethanol solution |
| Ultraschallreinigung | Built-in ultrasonic bath for protein and salt crystal buildup Programmable in hours and minutes, up to 60 minutes (model dependent) |
| Volumen Pufferflasche | 4 L or 10 L (optional) |
| Technische Merkmale | |
| Maße | Depth: 17" (43.2 cm) Width: 14" (35.6 cm) Height: 10" (25.4 cm) |
| Gewicht | With internal buffer switching - 36 lbs (16.5 kg) Without - 30 lbs (13.5 kg) |
| Vorschrift | |
| Vorschrift | For In Vitro Diagnostic use. All BioTek microplate instrumentation is CE and TUV marked. |
Änderungen vorbehalten.
Optional

BioStack Mikroplatten-Stacker

LHC Liquid Handling Control™ Software
Standard (enthalten) | ||
Handbuch | ||
| MANUAL | Operator's manuals can be obtained via the Customer Resource Center | |